Search results for "Acceleration voltage"

showing 4 items of 4 documents

Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy

2011

A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measurements. Beam velocity measurements using frequencycomb based collinear laser spectroscopy agree with the new calibration. Applying this, one obtains consistent results for isotope shifts of stable magnesium isotopes measured using collinear spectroscopy and laser spectroscopy on laser-cooled ions in a trap. The long-term stability and the transient behavior during recovery from a voltage dropout were…

PhysicsNuclear and High Energy PhysicsIon beamAtomic Physics (physics.atom-ph)Voltage dividerOther Fields of PhysicsFOS: Physical sciencesLaserAcceleration voltagelaw.inventionPhysics - Atomic PhysicslawCalibrationPhysics::Accelerator PhysicsPhysics::Atomic PhysicsAtomic physicsDetectors and Experimental TechniquesSpectroscopyNuclear ExperimentInstrumentationBeam (structure)Voltage
researchProduct

Beamline pulsing system for cyclotrons

1998

Abstract A beamline pulsing system for cyclotrons is presented. The function of this system is to modify the structure of a cyclotron ion beam guided to the desired research target by a beamline. In some in-beam experiments, an adjustment of the time structure of the beam is sometimes needed. This kind of situation occurs if, for example, the life time of the target material is longer than the period corresponding to the beam frequency. In this case, the frequency of the ion pulses hitting the target is 10–21 MHz depending on the frequency of the acceleration voltage. The adjustment of the ion beam pulse frequency is carried out by a beamline deflector. Deflection is achieved by feeding a h…

PhysicsNuclear and High Energy PhysicsIon beambusiness.industryCyclotronAcceleration voltagelaw.inventionIonFrequency dividerSignal levelOpticsBeamlineDeflection (engineering)lawbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The Collinear Fast Beam laser Spectroscopy (Cfbs) experiment at Triumf

2016

Abstract Laser spectroscopy experiments at radioactive ion beam facilities around the world investigate properties of exotic nuclei for scientific endeavours such as, but not limited to, the investigation of nuclear structure. Advancements in experimental sensitivity and performance are continuously needed in order to extend the reach of nuclei that can be measured. The collinear fast beam laser spectroscopy ( Cfbs ) setup at Triumf , coupled to an out-of-plane radio-frequency quadrupole Paul trap, enables measurements of some of the most fundamental nuclear properties for long-lived ground and isomeric states. The first comprehensive overview of the Cfbs experiment is provided along with d…

PhysicsNuclear and High Energy PhysicsPhotonta114Ion beamcollinear laser spectroscopy010308 nuclear & particles physicsbusiness.industrymulti-dimensional data acquisition system01 natural sciences7. Clean energyAcceleration voltagehigh-frequency intensity modulationOpticsData acquisition0103 physical sciencesQuadrupoletime-resolved fluorescence spectroscopyIon trap010306 general physicsSpectroscopybusinessrapid frequency switchingInstrumentationHyperfine structureNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Spatial distribution of air kerma rate and impact of accelerating voltage on the quality of an ultra soft X-ray beam generated by a cold cathode tube…

2015

Abstract Ultrasoft X-ray characteristic aluminum K alpha line (Al Kα with energy of 1.5 keV) is used in radiobiological experiments to study the effect of radiation on biological matter. A simple method to generate a continuous beam of those X-ray radiations is to bombarding an aluminum target with accelerated electrons using high voltage (HV). In this work, by varying the HV we study the characteristics of a photon beam generated by means of a cold cathode transmission X-ray tube. The anode is a thin (16 μm) aluminum foil supported by a copper grid. The spatial distribution of air kerma is measured using gafchromic films of HD-810 calibrated with a parallel plate free-air ionization chambe…

PhysicsRadiationbusiness.industryX-ray tubeAcceleration voltageCathodelaw.inventionAnodeKermaOpticslawIonization chamberCold cathodeAtomic physicsbusinessInstrumentationBeam (structure)Radiation Measurements
researchProduct